AJSM 2015
Recent biomechanical evidence suggests that the meniscus-suture interface contributes the most displacement to the transtibial pull-out repair for meniscal root tears. Therefore, optimization of surgical technique at the meniscus-suture interface may minimize displacement and improve the strength of meniscal root repairs.
The purpose of this study was to investigate the cyclic displacement and ultimate failure loads of 4 differ- ent meniscus-suture fixation techniques for posterior medial meniscal root repairs in human meniscus tissue. The hypothesis was that there would be no significant difference between the two simple sutures (TSS) technique and 3 other techniques in cyclic displacement or ultimate failure load.